FOR PRINTABLE COPY OF THE PVC SPECS CLICK HERE [PDF READER REQUIRED]

10 Mil PVC Geomembrane 

Certified Properties Test Method Requirement
Thickness 5% ASTM-D5199 .010"
Specific Gravity (min.) ASTM-D792 1.20
100% Modulus - lb. force/in. width, min. ASTM-D882 10
Tensile - lb. force/in. width, min. ASTM-D882 24
Elongation at Break (%, min.) ASTM-D882 250
Graves Tear (lb./in., min.) ASTM-D1004 2.5
Impact Cold Crack (C) ASTM-D1790 -23
     
Index Properties    
Resistance to Soil Burial (% change max.) ASTM-G160  
     1. Breaking Factor   5
     2. Elongation at Break   20
     3. Modulus at 100% Elongation   20
Impact Cold Crack (C) ASTM-D1790 -23
Dimensional Stability (% change max.) ASTM-D1204 4
Water Extraction (%, max.) ASTM-D1239 0.15
Volatile Loss (%, max.) ASTM-D1203(A) 1.5
Hydrostatic Resistance (psi, min.) ASTM-D751(A) 42
 
Minimum Specifications for Factory Fabricated Seams:
Peel Strength, lbs/in. width ASTM-D882 10 / FTB
Shear Strength, lbs/in. width ASTM-D882 20

20 Mil PVC Geomembrane

Certified Properties Test Method Requirement
Thickness 5% ASTM-D5199 .020"
Specific Gravity (min.) ASTM-D792 1.20
100% Modulus - lb. force/in. width, min. ASTM-D882 21
Tensile - lb. force/in. width, min. ASTM-D882 48
Elongation at Break (%, min.) ASTM-D882 360
Graves Tear (lb./in., min.) ASTM-D1004 6
Impact Cold Crack (C) ASTM-D1790 -26
     
Index Properties    
Resistance to Soil Burial (% change max.) ASTM-G160  
     1. Breaking Factor   5
     2. Elongation at Break   20
     3. Modulus at 100% Elongation   20
Dimensional Stability (% change max.) ASTM-D1204 4
Water Extraction (%, max.) ASTM-D1239 0.15
Volatile Loss (%, max.) ASTM-D1203(A) 0.9
Hydrostatic Resistance (psi, min.) ASTM-D751(A) 68
 
Minimum Specifications for Factory Fabricated Seams:
Peel Strength, lbs/in. width ASTM-D882 12.5
Shear Strength, lbs/in. width ASTM-D882 38.4

30 Mil PVC Geomembrane

Certified Properties Test Method Requirement
Thickness 5% ASTM-D5199 .030"
Specific Gravity (min.) ASTM-D792 1.20
100% Modulus- lb. force/in. width, min. ASTM-D882 32
Tensile - lb. force/in. width, min. ASTM-D882 73
Elongation at Break (%, min.) ASTM-D882 380
Graves Tear (lb./in., min.) ASTM-D1004 8
Impact Cold Crack (C) ASTM-D1790 -29
     
Index Properties    
Resistance to Soil Burial (% change max.) ASTM-G160  
     1. Breaking Factor   5
     2. Elongation at Break   20
     3. Modulus at 100% Elongation   20
Dimensional Stability (% change max.) ASTM-D1204 3
Water Extraction (%, max.) ASTM-D1239 0.15
Volatile Loss (%, max.) ASTM-D1203(A) 0.70
Hydrostatic Resistance (psi, min.) ASTM-D751(A) 100
 
Minimum Specifications for Factory Fabricated Seams:
Peel Strength, lbs/in. width ASTM-D882 15
Shear Strength, lbs/in. width ASTM-D882 58.4

40 Mil PVC Geomembrane

Certified Properties Test Method Requirement
Thickness 5% ASTM-D5199 .040"
Specific Gravity (min.) ASTM-D792 1.20
100% Modulus - lb. force/in. width, min. ASTM-D882 40
Tensile - lb. force/in. width, min. ASTM-D882 97
Elongation at Break (%, min.) ASTM-D882 430
Graves Tear (lb./in., min.) ASTM-D1004 10
Impact Cold Crack (C) ASTM-D1790 -29
     
Index Properties    
Resistance to Soil Burial (% change max.) ASTM-G160  
     1. Breaking Factor   5
     2. Elongation at Break   20
     3. Modulus at 100% Elongation   20
Dimensional Stability (% change max.) ASTM-D1204 3
Water Extraction (%, max.) ASTM-D1239 0.20
Volatile Loss (%, max.) ASTM-D1203(A) 0.50
Hydrostatic Resistance (psi, min.) ASTM-D751(A) 120
 
Minimum Specifications for Factory Fabricated Seams:
Peel Strength, lbs/in. width ASTM-D882 15
Shear Strength, lbs/in. width ASTM-D882 77.6

50 Mil PVC Geomembrane 

Certified Properties Test Method Requirement
Thickness 5% ASTM-D5199 .050"
Specific Gravity (min.) ASTM-D792 1.20
100% Modulus  - lb. force/in. width, min. ASTM-D882 50
Tensile - lb. force/in. width, min. ASTM-D882 116
Elongation at Break (%, min.) ASTM-D882 430
Tear Strength (lb./in., min.) ASTM-D1004 13.0
Low Temp Impact (C) ASTM-D1790 -29
     
Index Properties    
Resistance to Soil Burial (% change max.) ASTM-G160  
     1. Breaking Factor   5
     2. Elongation at Break   20
     3. Modulus at 100% Elongation   20
Dimensional Stability (% change max.) ASTM-D1204 3
Water Extraction (%, max.) ASTM-D1239 0.20
Volatile Loss (%, max.) ASTM-D1203(A) 0.50
Hydrostatic Resistance (psi, min.) ASTM-D751(A) 150
 
Minimum Specifications for Factory Fabricated Seams:
Peel Strength, lbs/in. width ASTM-D882 15
Shear Strength, lbs/in. width ASTM-D882 96.0

60 Mil PVC Geomembrane 

Certified Properties Test Method Requirement
Thickness 5% ASTM-D5199 .060"
Specific Gravity (min.) ASTM-D792 1.20
100% Modulus - lb. force/in. width, min. ASTM-D882 60
Tensile - lb. force/in. width, min. ASTM-D882 137
Elongation at Break (%, min.) ASTM-D882 450
Tear Strength - (lb./in., min.) ASTM-D1004 15.0
Low Temp Impact (C) ASTM-D1790 -29
     
Index Properties    
Resistance to Soil Burial (% change max.) ASTM -G160  
     1. Breaking Factor   5
     2. Elongation at Break   20
     3. Modulus at 100% Elongation   20
Dimensional Stability (% change max.) ASTM-D1204 3
Water Extraction (%, max.) ASTM-D1239 0.20
Volatile Loss (%, max.) ASTM-D1203(A) 0.50
Hydrostatic Resistance (psi, min.) ASTM-D751(A) 180
 
Minimum Specifications for Factory Fabricated Seams:
Peel Strength, lbs/in. width ASTM-D882 15
Shear Strength, lbs/in. width ASTM-D882 116

 
FOR PRINTABLE COPY OF THE PVC SPECS CLICK HERE [PDF READER REQUIRED]

Return To Geomembranes Products Page
Return To PVC Products Page

Pond Liner Calculator

Divider

 [HOME | PRODUCTS | SPECIALS | RELATED INFORMATION]
[CONTACT US! | WHAT'S NEW | ABOUT]
 

Divider

GeoCHEM, Inc. Business Page 1997 - 2007 GeoCHEM, Incorporated All Rights Reserved. 
Visit Often for Our Latest Page Developments And Updates! Last Updated: 10/17/13 01:14:32 PM