Detector Loop Install Guideline Specs

Detector Loop Installation Guidelines & Technical Specifications

PART 1: GENERAL

1.1 SCOPE

A. This work consists of the installation and encapsulation of traffic detector loops in Portland Cement Concrete (PCC) and Asphalt Concrete (AC) pavements. B. The installation shall be performed in accordance with Section [Insert Local Section] of the Standard Specifications, using a high-performance, rapid-setting urethane resin system.

1.2 SUBMITTALS

A. Installation Procedures: Submit detailed protocols for production, placement, and finishing. B. Safety Data: Maintain and follow Manufacturer Safety Data Sheets (SDS) for all chemical components.

PART 2: MATERIALS

2.1 LOOP SEALER (Percol® Elastic Cement AC Grade)

The loop sealer shall be a two-component, 100% solids, rapid-setting urethane resin mixed in equal volumes (1:1).

Physical Properties:

Property Component A Component B
Viscosity at 73°F (ASTM D2393) 70 cps 180 cps
Specific Gravity (approx.) 1.10 1.03
Appearance Brown Black

 

IDOT Compliance: Detector Loop Installation Standards

Supplemental Specifications for Illinois Department of Transportation (District 1)

This work consists of furnishing and installing a Detector Loop in accordance with the requirements of Section T418 of the Traffic Specifications and revised herein.

1. Approved Sealant: Percol® Elastic Cement AC Grade

IDOT standards require a two-component, 100% solids urethane resin. Percol® Elastic Cement AC meets or exceeds all IDOT physical property requirements, providing a 10-minute cure time and superior bond strength to both asphalt and concrete substrates.

1.1 Liquid Component Properties

Property Component A (Isocyanate) Component B (Polyol)
Ratio (A:B by Volume) 1 1
Viscosity @ 73°F (ASTM D2393) 70 cps 180 cps
Appearance Brown Black
Specific Gravity @ 73°F 1.10 1.03

1.2 Cured Material Performance

Physical Property Test Method Requirement
Specific Gravity ASTM D-792 1.06 to 1.10
Hardness (Durometer D) ASTM D-2240 45 to 65
Tensile Strength ASTM D-412 1,600 psi (min)
Compression Strength ASTM C-39 800 psi (min)
Elongation at Break (%) ASTM D-412 140% (min)
Tear Strength ASTM D-624 150 (min)
Pot Life @ 73°F ~60 Seconds
Traffic Ready / Cure ~10 Minutes

2. Installation & Preparation

  • Pavement Selection: Loops must miss existing joints and cracks if possible.

  • Trenching: Saw cuts must be 1.5" minimum to 2.0" maximum deep. Width must be a minimum of 5/16".

  • Corner Treatment: All corners must be drilled with 2" cores to the depth of the saw cut. Saw cuts across corners are NOT allowed.

  • Cleaning: Use compressed air, wire brushing, and heat drying. Saw cuts must be free of debris, dust, and water residue immediately prior to sealing.

  • Wire Positioning: Detector wire must be held 1.0" below the surface using form wedges spaced no more than 18" apart.

  • Lead-in: Wire from the loop to the handhole must have six twists per foot.

3. Engineering Inductance Formulas

Calculations must be furnished to the Area Signal Engineer at the time of inspection:

  • Single Loop (4-Sided):

  • Connected in Series:

  • Lead-In Cable:

  • Inductance Ratio: Ideal ratio of total loop inductance to lead-in is 2:1 (Minimum allowable is 1:7).

4. Final Identification & Payment

4.1 Labeling

Each lead-in wire must be labeled in the handhole using a Panduit 250W1175C waterproof tag (or approved equal) secured with nylon ties. Tags must indicate location, rotation (CW/CCW), lead-in direction, loop cable number, and number of turns in waterproof ink.

4.2 Basis of Payment

This work will be paid for at the contract unit price per lineal foot for DETECTOR LOOP, which is payment in full for furnishing, installing, and testing. Measurement is taken along the raceway in the pavement. (Note: 6' round loops may be substituted for 6'x6' square loops and are paid as 24 lineal feet).

5. Reference Standards

Standards Organization Reference Codes
ASTM C-33, C-39, D-412, D-624, D-792, D-2240, D-2393
AASHTO T-84, T-85

 